Munters ARG 100 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chauffe-eau et chaudières Munters ARG 100. Munters ARG 100 User`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - User’s Manual

190TGB-1034 © Munters Europe AB 2002ML/MLT180-350User’s ManualDesiccant DehumidifierML180-MLT350Effective for units manufactured from week 46, 2002

Page 2

ML180-MLT350 Dehumidifiers102 Installation 190TGB-1034-A2.8 Ducting2.8.1 General recommendationsThe connections for process and reactivation air are d

Page 3 - Contents

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 11• The total resistance in the process and reactivation air ductwork must not exceed the perfo

Page 4 - Important user information

ML180-MLT350 Dehumidifiers122 Installation 190TGB-1034-AFigure 2-4. Outdoor air inlet designFigure 2-5. Required ductwork2.9 Precaution for unit using

Page 5 - 1 Introduction

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 132.10 Installation Examples2.10.1 Closed SystemFigure 2-6. Closed Airflow System2.10.2 Open Sy

Page 6 - (DE) FILTER AUSWECHSELN

ML180-MLT350 Dehumidifiers142 Installation 190TGB-1034-A2.11 Electrical Connections2.11.1 Mains SupplyWARNING! All electrical equipment connections m

Page 7 - 2 Installation

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 15 The humidistat must be electrically compatible with the dehumidifier’s extra low voltage co

Page 8 - 2.5 Storing the Equipment

ML180-MLT350 Dehumidifiers162 Installation 190TGB-1034-A7. The ML270 has a 3 phase fan motor and the rotation direction of the fan impeller must be ch

Page 9 - 2.6 Location Requirements

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 174. If the temperature differential is out of tolerance limit by 5%, adjust the reactivation a

Page 10 - 2.8 Ducting

ML180-MLT350 Dehumidifiers183Operation 190TGB-1034-A3 Operation3.1 GeneralThe ML180-MLT350 dehumidifiers are equipped with a control panel that contai

Page 11 - 2 Installation 11

ML180-MLT350 Dehumidifiers190TGB-1034-A 3 Operation 195. Operate the run/stop switch to the position and check that the unit stops and that the unit

Page 13 - 2.10 Installation Examples

ML180-MLT350 Dehumidifiers203Operation 190TGB-1034-A5. Operate the run/stop switch to the position and check that the unit stops and that the unit r

Page 14 - and must have an insulation

ML180-MLT350 Dehumidifiers190TGB-1034-A 4 Maintenance 214 Maintenance4.1 GeneralMunters dehumidifiers are designed for long, continuous operation with

Page 15 - 2.13 Pre-Start settings

ML180-MLT350 Dehumidifiers224 Maintenance 190TGB-1034-AComponentInspection/Maintenance Procedure3-6 Months 12 MonthsProcess and reactivation filterCle

Page 16

ML180-MLT350 Dehumidifiers190TGB-1034-A 5 Fault Finding 235 Fault Finding5.1 GeneralThe purpose of this chapter is to provide guidance in basic fault

Page 17 - 2 Installation 17

ML180-MLT350 Dehumidifiers245 Fault Finding 190TGB-1034-AFigure 5-1. Control Panel Fault SymptomIndicators Possible cause ActionUnit has stoppedAll of

Page 18 - 3 Operation

M180-MLT350 Dehumidifiers190TGB-1034-A 6 Product Design Information 256 Product Design Information6.1 Product DescriptionThe ML-Series desiccant dehum

Page 19 - 3 Operation 19

M180-MLT350 Dehumidifiers266 Product Design Information 190TGB-1034-A6.3 Dimensions and service spaceScaled and dimensioned AutoCAD drawings are avail

Page 20 - 3.6 Control Panel

M180-MLT350 Dehumidifiers190TGB-1034-A 6 Product Design Information 276.4 Capacity DiagramsApproximate capacity in kg/h.For detailed information, plea

Page 21 - 4 Maintenance

M180-MLT350 Dehumidifiers286 Product Design Information 190TGB-1034-A6.5 Technical Specifications Model ML180 ML270 MLT350Process Air1Rated Airflow (m

Page 22 - 4 Maintenance 190TGB-1034-A

M180-MLT350 Dehumidifiers190TGB-1034-A 6 Product Design Information 296.6 Unit’s main componentsFigure 6-4. General Assembly12345678910111213141516171

Page 23 - 5 Fault Finding

ML180-MLT350 Dehumidifiers190TGB-1034-A02.10 Contents 3ContentsImportant user information...41 Introduction1.1 General ...

Page 24 - 5 Fault Finding 190TGB-1034-A

ML180-MLT350 Dehumidifiers307 Appendix 1- Options 190TGB-1034-A7 Appendix 1- Options7.1 GeneralML180-MLT350 dehumidifiers have been designed to ensure

Page 25 - 6 Product Design Information

ML180-MLT350 Dehumidifiers190TGB-1034-A 7 Appendix 1- Options 31The push buttons have the following main functions:SET Display/change the required val

Page 26 - M180-MLT350 Dehumidifiers

ML180-MLT350 Dehumidifiers327 Appendix 1- Options 190TGB-1034-A7.4.4 Process related alarmsThe operator panel is equipped with an internal alarm, that

Page 27 - 6.4 Capacity Diagrams

ML180-MLT350 Dehumidifiers190TGB-1034-A 7 Appendix 1- Options 33Acknowledge alarmsAcknowledge the alarm by pressing SET on the operator panel. The dis

Page 28 - 6.5 Technical Specifications

ML180-MLT350 Dehumidifiers347 Appendix 1- Options 190TGB-1034-A

Page 30 - 7 Appendix 1- Options

ARGENTINAMunters ArgentinaBUENOS AIRESTel: +54 (0)11 4902 1874Fax: +54 (0)11 4902 1823AUSTRALIAMunters Pty NORTH ALBURYTel: +61 (0) 260 256 422Fax: +

Page 31 - 7 Appendix 1- Options 31

ML180-MLT350 Dehumidifiers4Important user information 190TGB-1034-AImportant user informationIntended use of equipmentMunters dehumidifiers are intend

Page 32 - 1-15 %RH

ML180-MLT350 Dehumidifiers190TGB-1034-A 1 Introduction 51 Introduction1.1 GeneralMunters dehumidifiers are designed to efficiently dehumidify air. Mun

Page 33 - 7 Appendix 1- Options 33

ML180-MLT350 Dehumidifiers61 Introduction 190TGB-1034-A1.4 MarkingsFigure 1-1. Location of labels Figure 1-2. Example of identification plate content

Page 34 - ML180-MLT350 Dehumidifiers

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 72 Installation2.1 GeneralThe ML Dehumidifiers intended for indoor installation.The unit is ins

Page 35

ML180-MLT350 Dehumidifiers82 Installation 190TGB-1034-A2.3 Moving the EquipmentWARNING! The dehumidifier is heavy and can weigh in excess of 50kg. To

Page 36

ML180-MLT350 Dehumidifiers190TGB-1034-A 2 Installation 92.6 Location RequirementsThe dehumidifier is intended for indoor installation.It is important

Commentaires sur ces manuels